Animal search form
    

21 of 249 animals listed.

Animal Investigator, Project Sessions Actions Updated
MS21
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
88 Surgeries
2018-06-13, 11:45: 12:10. 250 grams.

Probe implants
Silicon probe NeuroNexus Buzsaki64sp (64 ch, 6 shanks, staggered Non-uniform ) | HIP | (-3.3,-2.5,-1.6)
Silicon probe NeuroNexus Buzsaki64 (64 ch, 8 shanks, staggered) | HIP | (-3.3,2.5,1.6)

2020-06-26 20:32:40
by Peter
MS23
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
2 Surgeries
2019-08-20, 13:30: 21:00. 340 grams.
2020-06-26 20:32:37
by Peter
MS13
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
14 Surgeries
2017-10-31, 10:30: 20:10. 320 grams.
Probe implants
Silicon probe Cambridge Neurotech P1-64ch (64 ch, 4 shanks, poly 2 ) | HIP | (-3.3,2.5,-1.6)
Silicon probe Cambridge Neurotech P1-64ch (64 ch, 4 shanks, poly 2 ) | HIP | (-3.3,-2.5,-1.6)
2020-06-26 20:32:34
by Peter
MS5
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-07-29, 10:33: 17:00. 400 grams.
2020-06-26 20:32:32
by Peter
MS4
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-07-25, 10:45: 17:00. 410 grams.
2020-06-26 20:32:30
by Peter
MS12
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
13 Surgeries
2017-06-17, 11:20: 21:00. 410 grams.
Probe implants
Silicon probe NeuroNexus Buzsaki 5×12 (64 ch, 5 shanks, staggered Non-uniform) | HIP | (-3.3,2.5,-1.6)
Silicon probe NeuroNexus Buzsaki 5×12 (64 ch, 5 shanks, staggered Non-uniform) | HIP | (-3.3,-2.5,-1.6)
Manipulations:
Thermal perturbation, Cooling probe (MS - Medial septal nucleus, 0.7,0.2,6.5) [loggedin]Duplicate [/loggedin]
2020-06-26 20:32:28
by Peter
MS10
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
14 Surgeries
2017-02-22, 10:35: 18:50. 395 grams.
Probe implants
Silicon probe NeuroNexus Buzsaki 5×12 (64 ch, 5 shanks, staggered Non-uniform) | HIP | (-3.3,-2.5,1.6)
2020-06-26 20:32:26
by Peter
MS9
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-12-08, 11:00: 18:40. 330 grams.
Probe implants
Silicon probe Cambridge Neurotech P1-64ch (64 ch, 4 shanks, poly 2 ) | HIP | (-3.3,-2.5,-1.6)
2020-06-26 20:32:23
by Peter
MS8
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-11-09, 11:48: 20:00. 390 grams.
Probe implants
5×50µm Single wires | HIP | (-3.3,-2.5,-2.2)
3×50µm Single wires | MS | (,-0.4,-7.5)
2020-06-26 20:32:20
by Peter
MS7
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-10-04, 11:30: 20:30. 500 grams.
Probe implants
1×50µm Single wires | MS | (,-0.4,-7.5)
4×50µm Single wires | HIP | (-3.3,-2.5,-2.7)
2020-06-26 20:32:18
by Peter
MS6
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-09-12, 11:25: 19:30. 400 grams.
Probe implants
5×50µm Single wires | HIP | (-3.3,-2.5,-2.2)
2020-06-26 20:32:15
by Peter
MS3
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-06-19, 12:00: 19:10. 480 grams.
Probe implants
8×50µm Single wires | MS | (,-0.4,-7.5)
2020-06-26 20:32:13
by Peter
MS2
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Surgeries
2016-06-01, 10:40: 19:40. 380 grams.
Probe implants
Silicon probe NeuroNexus Buzsaki 5×12 (64 ch, 5 shanks, staggered Non-uniform) | HIP | (-3.7,2.0,-1.5)
2020-06-26 20:32:10
by Peter
MS14
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
7 Probe implants
Silicon probe NeuroNexus Buzsaki A4x16_poly3_6mm20s_200_160 (64 ch, 4 shanks, poly 3 Custom) | HIP | (-3.3,-2.5,-1.6)
Silicon probe NeuroNexus Buzsaki A4x16_poly3_6mm20s_200_160 (64 ch, 4 shanks, poly 3 Custom) | HIP | (-3.3,2.5,-1.6)
2020-06-26 20:32:08
by Peter
MS15
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:32:05
by Peter
MS16
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:32:03
by Peter
MS17
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:32:00
by Peter
MS18
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
11 Surgeries
2018-05-02, 13:00: 22:20. 540 grams.
Probe implants
Silicon probe NeuroNexus Buzsaki A4x16_poly3_6mm20s_200_160 (64 ch, 4 shanks, poly 3 Custom) | HIP | (-3.3,2.5,-1.6)
Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:31:58
by Peter
MS20
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:31:55
by Peter
MS19
Male, Rat, Long Evans
Wild type
Peter Petersen
Theta rhythm perturbation by focal cooling of the septal pacemaker in awake rats
0 Virus injections
AAV8-hSyn-SwiChR-++-eYFP (Stanford Vector Core) | MS
2020-06-26 20:31:52
by Peter